The drum has play, is off-centre or has dropped

The tub assembly can move on its suspension; this is not the same as play in the inner drum relative to the tub. If the drum is permanently off-centre, rubbing or has dropped, stop using the appliance.

Observe which part is moving

Unplug the appliance before carrying out any accessible checks. In a front-loading machine, it is important to distinguish movement of the entire suspended assembly from movement of the inner drum relative to it. Do not lift it forcefully or assume there is a universal acceptable amount of play: behaviour depends on the design.

Note whether the gap around the opening is uneven, whether there are marks on the seal, or whether slight movement causes contact. Do not run a spin cycle just to document a knocking sound that is already obvious.

What the service technician should check

The suspension supports and controls the tub assembly. The bearings and the support or shaft help support the inner drum. Identifying which mechanical relationship has changed makes it possible to inspect the correct assembly.

Wear or damage can affect more than one area. If a rubbed seal is replaced without correcting the misalignment, contact may occur again. A door leak accompanied by rubbing should be described along with the play.

Information that helps assess the repair

Provide the model number, when the problem began, whether there was gradually increasing noise or a sudden knock, and whether there had been any leaks. The technician should confirm the damage and availability of the relevant assembly before providing a quote.

Adjusting the feet to level the appliance will not correct a drum that moves relative to its own internal supports.