The tub assembly can move on its suspension; this is not the same as play in the inner drum relative to the tub. If the drum is permanently off-centre, rubbing or sagging, stop using the appliance.
Observe which part moves
Unplug the appliance before carrying out any accessible checks. With a horizontal-axis drum, distinguish between movement of the entire suspended assembly and movement of the inner drum relative to it. Do not lift it forcefully or look for a universal tolerance: how it behaves depends on its design.
Note whether the gap around the opening is uneven, whether there are marks on the seal, or whether slight movement causes contact. Do not run a spin cycle to document a banging noise that is already obvious.
What the service technician should check
The suspension supports and controls the tub assembly. The bearings and the support or shaft help support the inner drum. Identifying which mechanical relationship has changed helps the technician inspect the right assembly.
Wear or damage can affect more than one area. If a rubbed seal is replaced without correcting the misalignment, contact may happen again. A door leak accompanied by rubbing should be described along with the play.
Useful information for assessing the repair
Provide the model, when the problem started, whether there was increasing noise or a sudden bang, and whether there had been any earlier leaks. The technician should confirm the damage and the availability of the relevant assembly before providing an estimate.
Levelling the feet will not fix a drum that moves relative to its own internal supports.