Water trays and detectors: protecting the installation space

A tray contains some of the water; a detector senses water at its contact point; an external valve can shut off the supply. None of these measures repairs a leak or necessarily covers every path the water may take.

What each measure can do

Protecting the installation space
MeasureScopeMain limitation
Tray without a drainHolds a limited volumeMay overflow if the leak continues
Tray with a drainDirects collected water to a designated outletDepends on installation and drainage capacity
Point detectorSounds an alert when water reaches its sensorDoes not detect water taking another path
External automatic shut-offShuts off a supply point when activatedDoes not cover leaks upstream of the shut-off or water already present

Physical compatibility and access

The tray must accommodate the appliance’s dimensions and feet, and allow it to operate without affecting its support. Its edge must not block access to a filter or removal of the appliance for servicing. Position the detector where it can receive water from the area being protected, in accordance with its instructions.

A tray outlet requires suitable drainage; do not connect it to just any pipe by guesswork or block drains to prevent odours.

Built-in protection and protection of the surrounding area

The appliance’s leak-protection systems operate within its own design. External measures protect aspects of the installation location. If a protective measure repeatedly gives an alert, find the leak rather than adding larger containers so you can keep washing.

Choose each measure based on the path of water it can actually detect or contain.