A tray contains some of the water; a detector senses water at its point of contact; an external valve can cut off the supply. None of these measures repairs a leak or necessarily covers all the paths it may take.
What each measure can do
| Measure | Scope | Main limitation |
|---|---|---|
| Tray without a drain | Holds a limited volume | May overflow if the leak continues |
| Tray with a drain | Carries collected water to a designated outlet | Depends on installation and drainage capacity |
| Point detector | Alerts when water reaches its sensor | Does not detect water taking another path |
| External automatic shut-off | Cuts off one supply point when activated | Does not cover leaks upstream of the shut-off or water already present |
Physical compatibility and access
The tray must accommodate the appliance’s dimensions and feet, and allow it to operate without affecting its support. Its edge must not block the opening of a filter or removal of the appliance for servicing. Place the detector where it can receive water from the area to be protected, as specified in its instructions.
A tray outlet requires suitable drainage; do not connect it to just any pipe based on guesswork, or block drains to prevent odours.
Integrated protection and protection of the surroundings
The machine’s leak-protection systems operate within its design. External measures protect aspects of the installation location. If a protection system gives repeated alerts, find the leak rather than adding larger containers so you can keep washing.
Choose each measure based on the path of water it can actually detect or contain.