A solenoid valve can fail to open or close, but a lack of water may also be caused by the water supply or the control system. Continuity in its coil does not prove that it seals correctly.
Distinguish between the symptoms
If not enough water is entering, first check the water supply, hose and filters using the permitted procedure. If water enters while the appliance is switched off, investigate mechanical closure and external backflow.
In a multi-way valve, the fault may affect only one inlet or path. Diagnosing hot and cold water inlets helps avoid attributing the problem to the entire valve assembly without checking each function.
What the repair should include
The compatible part identification must take account of the ways, connectors and water connections. Before accessing the valve, isolate the electricity and water supply, and contain any residual water.
The Electrolux procedure for its documented valve pays particular attention to seals, connectors and clamps during assembly. The access method and fixings in that example are not a universal procedure.
The replacement must preserve the routing of the hoses and restore the specified seals. Once the appliance is fully reassembled, check filling, shut-off and for leaks.
Tests that require documentation
Assess the coil, power supply and control signal using the applicable wiring diagram. Do not power the valve outside the appliance or attempt to repair a sealed diaphragm unless the manufacturer specifies this operation.
The repair report should explain whether the fault affected opening, flow rate or sealing; these are different functions of the same part.