A solenoid valve can fail to open or close, but a lack of water may also be caused by the water supply or the controls. Continuity across its coil does not prove that it seals correctly.
Distinguish between the symptoms
If not enough water enters, first check the water supply, hose and filters using the permitted procedure. If water enters while the appliance is switched off, investigate a mechanical failure to close and external backflow.
In a multi-way valve, the fault may affect just one inlet or flow path. Diagnosing the hot and cold inlets helps avoid blaming the whole valve assembly without checking each function.
What the repair should involve
The compatible replacement must match the ports, connectors and water connections. Before gaining access, isolate the electricity and water supply, and contain any residual water.
The Electrolux procedure for the valve covered in its documentation highlights the importance of seals, connectors and clips during reassembly. The access method and fixings shown in that example are not a universal procedure.
The replacement must preserve the pipe routing and restore the specified seals. Once the appliance is fully reassembled, check that it fills and shuts off correctly and that there are no leaks.
Tests requiring documentation
Assess the coil, power supply and control signal using the relevant wiring diagram. Do not power the valve outside the appliance or attempt to repair a sealed diaphragm unless the manufacturer specifies that this can be done.
The repair report should explain whether the fault affected opening, flow rate or watertightness; these are different functions of the same component.