The drain hose must be positioned at the specified height and connected as instructed for the model. Pumped drainage and gravity drainage do not necessarily use the same route.
Identify the type of outlet
The outlet may connect to a standpipe, a designated trap connection or a sink. The installation must handle the flow rate and temperature of the discharged water, while retaining the required protection against backflow. The connection for a portable washing machine may be temporary and secured differently.
Information from the manual to follow during installation
- Minimum and maximum height, if specified, and the point from which these are measured.
- Insertion depth and whether an air gap is required.
- Route length and approved extensions.
- Bend radius, support and method of securing.
- Accessories and type of connection to the building's drain.
The hose must remain secured without being crushed. Sealing a standpipe completely or inserting the hose too far can affect the intended ventilation. Measurements for another brand are no substitute for those specified for your appliance.
Why the machine may drain while filling
An incorrectly routed hose can create a siphoning flow. If the outlet relies on gravity, the difference in height plays a different role, and copying a raised route may prevent the water from draining. The water circuit can help you distinguish between the two designs.
For a shared drain, you should also check its capacity and whether water can flow back between appliances. If the machine fills and drains at the same time, note what happens and check the connection rather than assuming the pump has failed.
Before testing, compare the entire hose route with the diagram in the manual, including the washing machine's final position.
View all articles in Washing machine installation: requirements and checks