F8 E1, LF and Lo FL indicate filling problems on compatible Maytag models. Check the water supply and installation before trying to reset the machine.
Start with the taps, not the control panel
The manufacturer’s documentation for Maytag groups low-flow or slow-fill alerts together. First check whether the water has been turned off and whether the taps were closed after the machine was installed or moved. On machines with two inlets, open both taps if the manual requires it, even if you’ve selected a cold wash.
Check the visible section of each hose. If one is crushed, adjust its position without stretching the connections. Inlet screens should only be cleaned through the authorised access point, with the water turned off and the machine prepared for the task; see how to check those screens.
Water enters but isn’t retained
If you can hear the machine filling but it keeps waiting, note whether water is draining away at the same time. Compare the installation with the diagram for your model: an incorrectly positioned drain outlet can prevent the machine from retaining the required water level.
During fill protection, the control may drain the machine and temporarily become unresponsive. Allow it to wait, and follow the cancellation procedure on the control panel. If the fault returns despite the water supply and installation being correct, arrange a service call; repeatedly resetting the machine won’t distinguish a restriction from an internal fault.
Note whether both inlets fail or whether the problem depends on the selected temperature.