The element that heats the water can fail because of an open circuit or insulation breakdown. A continuity test only covers part of the diagnosis and does not prove that it is safe.
Confirm which part is not working
Start by checking the conditions for a wash cycle that does not heat: programme, water supply and expected behaviour. The water level, sensor or electrical control may also be involved. Not all appliances have a water heater.
Technical diagnosis distinguishes between an open circuit, faulty insulation and no heating command. If an electrical safety device trips, do not keep repeating cycles to see whether it happens at a particular stage.
Testing and replacement parts
Checks require model-specific information, suitable instruments and safe isolation. Continuity does not mean that insulation is adequate to protect the parts that need to remain protected.
The replacement part must match the geometry, specifications, seal and any applicable housings. The temperature sensor may need to be checked separately, even if it is close to the heater.
Fitting and validation
The Electrolux procedure for its documented heater includes draining beforehand and taking care with the seal. The rear access shown in that example is not universal.
Restore the position, fastening, connections and watertight seal in accordance with the manual, then carry out the specified electrical and functional checks. Tightening a seal further does not guarantee a better seal. The air heater in a washer-dryer is part of a different circuit and needs its own diagnosis.
A heater repair must verify both heating and electrical safety, as well as the seal on the tub that has been worked on.
View all articles in Washing machine component diagnosis and repair