Temperature sensor and thermostat: checking for faults

A temperature probe can only be assessed by comparing its response with the specification and the actual test temperature. A single reading is not enough to determine whether it is working or faulty.

Identify the component’s function

A resistive probe, such as an NTC thermistor where fitted, sends information to the control unit. A regulating thermostat switches according to its design. A safety limiter cuts out when a hazardous condition occurs. Being located near a heat source does not make these components interchangeable.

The documentation determines which components are present, where they operate, and whether they belong to the wash water or the drying circuit.

What distinguishes a reading fault

In the event of no heating or excessive temperature, the technician compares the thermal measurement, wiring and connectors with the control unit’s response. A broken wire can appear to indicate a faulty probe.

Testing a probe requires knowledge of the temperature and the manufacturer’s curve or table. A switching component must be tested under its own specified conditions. Values and methods must not be transferred from one component to another.

When to check other components

A correct reading does not confirm that the heating element is receiving the correct instruction. If a thermal protection device has tripped, investigate why that condition was reached before restoring operation.

Do not bypass limiters, adjust sealed thermostats or choose a probe by its shape or cable length. Any replacement must retain the required electrical characteristics, thermal contact, sealing and installation.

Record the reference temperature and method used alongside the diagnosis; without that context, a resistance reading provides little information.

View all articles in Washing machine component diagnosis and repair