Calibrating a Samsung washing machine after installing or moving it

On Samsung models with a calibration function, calibration adjusts the load-sensing reference. Run it with the drum empty and the machine level; it won’t fix damaged parts or an unsuitable support surface.

Confirm the panel family before pressing

The Samsung Caribbean calibration guide distinguishes between these panels. Use a procedure only if your model’s manual confirms that function and sequence:

Documented access by control family
Panel in the guideEntering the modeStarting calibration
Front-load model with Temperature and Delay EndTurn the machine off and on; hold both buttons for 3 seconds until Cb appearsHold Start/Pause
Multi-control panel with Additional FunctionsTurn the machine off and on; hold that button for 3 seconds; select calibration with the dialConfirm using the indicated O button
Top-load model with Wash Cycles and Delay EndWith the machine powered on, hold both buttons for at least 3 secondsHold Start/Pause
Top-load model with Water Level and Delay EndHold both buttons for at least 3 secondsHold Start/Pause

The drum performs calibration movements. Depending on the model, completion may be indicated by 0 or a calibration-complete message. Follow your manual if the controls or signals don’t match.

If the process is interrupted or the function doesn’t appear

Check that there are no clothes or objects in the drum and that levelling has been completed. Don’t try button combinations from other panels. Note the message and contact support if the process doesn’t finish as documented.

Load sensing helps control the cycle; calibration won’t repair a faulty suspension system or sensors. Then follow the relevant installation test.

Matching button names isn’t enough: confirm that your model includes this calibration procedure before running it.

View all articles in Commissioning and initial setup of a washing machine