On Samsung models with a calibration function, calibration adjusts the load-sensing reference. Run it with the drum empty and the machine level; it won’t fix damaged parts or an unsuitable support surface.
Confirm the panel family before pressing
The Samsung Caribbean calibration guide distinguishes between these panels. Use a procedure only if your model’s manual confirms that function and sequence:
| Panel in the guide | Entering the mode | Starting calibration |
|---|---|---|
| Front-load model with Temperature and Delay End | Turn the machine off and on; hold both buttons for 3 seconds until Cb appears | Hold Start/Pause |
| Multi-control panel with Additional Functions | Turn the machine off and on; hold that button for 3 seconds; select calibration with the dial | Confirm using the indicated O button |
| Top-load model with Wash Cycles and Delay End | With the machine powered on, hold both buttons for at least 3 seconds | Hold Start/Pause |
| Top-load model with Water Level and Delay End | Hold both buttons for at least 3 seconds | Hold Start/Pause |
The drum performs calibration movements. Depending on the model, completion may be indicated by 0 or a calibration-complete message. Follow your manual if the controls or signals don’t match.
If the process is interrupted or the function doesn’t appear
Check that there are no clothes or objects in the drum and that levelling has been completed. Don’t try button combinations from other panels. Note the message and contact support if the process doesn’t finish as documented.
Load sensing helps control the cycle; calibration won’t repair a faulty suspension system or sensors. Then follow the relevant installation test.
Matching button names isn’t enough: confirm that your model includes this calibration procedure before running it.
View all articles in Commissioning and initial setup of a washing machine