Find out the hardness from information provided by your water supplier or by testing the water entering the machine. Record the value and unit: foam, taste and clarity are not precise measurements.
Get a reading that represents your supply
If you receive water from a mains supply, check the report or ask your supplier. A regional map is no substitute for information about the supply to your home. If you use a well, have more than one supply or treat your water, you may need to test the relevant point.
When using a home test, follow the manufacturer’s instructions for sampling, reading and scale. Test strips give a range-based estimate; do not make up decimal places between colours. If the result will affect a treatment decision, confirm it using a suitably precise method.
Compare units before using a table
Hardness is usually expressed as calcium carbonate equivalent. The Maryland Geological Survey lists these common equivalents:
| Reading | Equivalent for this hardness expression |
|---|---|
| 1 mg/L as CaCO3 | Approximately 1 ppm in water |
| 1 gpg | Approximately 17.1 mg/L as CaCO3 |
For example, 10 gpg is approximately 171 mg/L as CaCO3. Do not compare that 10 directly with a table in mg/L. If the report uses French or German degrees, or another scale, check the conversion in the supply or test documentation before classifying the reading.
How to use the result
Check the detergent dosage table and the appliance’s maintenance requirements. The limits for soft or hard water may differ on a product label; use the scale in the document you are consulting.
The reading helps you assess water softening and limescale prevention, but it does not prescribe a fixed amount of additive. If the water has been treated beforehand, use the treated-water reading and check that the treatment is maintained.
What hardness does not measure
It is not a measure of sand, iron, total salinity or the water’s safety. If the supply is brown or has an unusual smell, contact your supplier. When using well, rain or tank water, also check the conditions of that source; a hardness test strip will not resolve the issue.
Record the date, sample source, method, value and unit. If the supply or treatment changes, confirm the reading again before keeping the same settings.
View all articles in Limescale and water quality: caring for your washing machine